CLGYZ - BATTERY ELECTROLYTE VARIOUS GRADES (SEE SUPPL)
- MSDS: CLGYZ
- Manufacturer: TELEDYNE BATTER PRODUCTS TELEDYNE INC COMPANY
- Product Name: BATTERY ELECTROLYTE VARIOUS GRADES (SEE SUPPL)
- National Stock Number: 6140-01-214-0353
Product Identification
Product ID:BATTERY ELECTROLYTE VARIOUS GRADES (SEE SUPPL)
MSDS Date:03/01/2000
FSC:6140
NIIN:01-214-0353
Status Code:A
MSDS Number: CLGYZ
Responsible Party
REDLANDS, CA 92373
US
Emergency Phone: 1-800-535-5053 (INFOTRAC)
Info Phone: 909-793-3131
Preparer: NAHID TOOSSI
Cage: 84375
Contractor
Telephone: 909-793-3131
Cage: 84375
Ingredients
SULFURIC ACID
CAS: 7664-93-9
RTECS: WS5600000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NOT PROVIDED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE OVEREXPOSURE: SULFURIC ACID MAY
CAUSE IRRITATION TO THE EYES, NOSE AND THROAT. DIFFICULTY IN
BREATHING MAY BE EXPERIENCED. ACID SPLASHED IN THE EYES OR ON THE
SKIN MAY CAUSE BURNS OR IRRITATION. CHRONIC OVEREXPOSURE: REPEATED
PROLONGED EXPOSURE TO DILUTE SULFURIC ACID MAY CAUSE IRRITATION OF
THE SKIN. REPEATED OR PROLONGED EXPOSURE TO MIST OR VAPORS OF
SULFURIC ACID MAY CAUSE EROSION OF THE TEETH, CHRONIC IRRITATION
OF THE EYES OR CHRONIC INFLAMMATION TO THE NOSE, THROAT, AND
BRONCHIAL TUBES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: INHALATION OF ELECTROLYTE CAN CAUSE
BURNS OF THE UPPER RESPIRATORY TRACT. LUNG IRRITATION AND PULMONARY
EDEMA MAY OCCUR. SKIN CONTACT: MAY CAUSE BURNS OR LOCALIZED
IRRITATION. EYE CONTACT: MAY CAUSE IRRITATION, CORNEAL BURNS AND
CONJUNCTIVITIS. BLINDNESS OR SEVERE OR PERMANENT INJURY MAY RESULT.
INGESTION: MAY CAUSE BURNS TO THE MOUTH, ESOPHAGUS AND STOMACH.
Medical Cond Aggravated by Exposure:NOT PROVIDED
First Aid
First Aid:EYES: WASH IMMEDIATELY WITH LARGE AMOUNT OF WATER, LIFTING
THE LOWER AND UPPER LIDS CONTINUOUSLY. GET MEDICAL ATTENTION. SKIN:
IMMEDIATELY FLUSH THE EXPOSED AREA OF THE SKIN WITH LARGE AMOUNT OF
WATER . REMOVE ANY CONTAMINATED CLOTHING AND SHOES (THIS CAN BE
DONE WHILE UNDER SHOWER). GET MEDICAL ATTENTION. INHALATION: REMOVE
EMPLOYEE FROM AREA OF EXPOSURE TO FRESH AIR. IF PERSON IS NOT
BREATHING AN D HAS NO PULSE, PERFORM CPR. IF BREATHING IS
DIFFICULT. GIVE OXYGEN. GET IMMEDIATE MEDICAL ATTENTION. INGESTION:
GIVE EMPLOYEE LARGE AMOUNT OF WATER IF CONSCIOUS. DO NOT INDUCE
VOMITING. GET MEDICAL A TTENTION.
Fire Fighting
Extinguishing Media:USE DRY CHEMICAL OR CO2 EXTINGUISHER FOR SMALL
FIRES. WATER FOG FOR LARGE FIRES.
Unusual Fire/Explosion Hazard:WHILE BATTERY IS BEING CHARGED, HYDROGEN
GAS IS PRODUCED. BATTERY MAY EXPLODE IF HYDROGEN GAS IS TRAPPED
INSIDE THE BATTERY CASE. KEEP IGNITION SOURCES AWAY.
Accidental Release
Spill Release Procedures:ELECTROLYTE SHOULD BE ABSORBED WITH A
NON-ORGANIC TYPE ABSORBENT SUCH AS DRY SAND OR EARTH. AVOID
DILUTION WITH WATER.
Neutralizing Agent:USE SODA ASH OR BAKING SODA TO NEUTRALIZE
ELECTROLYTE.
Handling
Handling and Storage Precautions:NOT PROVIDED
Other Precautions:AVOID USE OF UNINSULATED TOOLS. DO NOT MAKE A
CONNECTION BETWEEN TWO BATTERY TERMINALS. PROVIDE SUFFICIENT
VENTILATION IN WORK AREA. HYDROGEN AND OXYGEN GASES ARE PRODUCED
DURING NORMAL BATTERY OPERA TION, ESPECIALLY DURING CHARGING. USE
EXHAUST SYSTEM CONNECTED DIRECTLY TO OUTSIDE AIR.
Exposure Controls
Respiratory Protection:UNDER NORMAL CONDITIONS OF USE RESPIRATORY
PROTECTION IS NOT REQUIRED. HOWEVER. SHOULD CONDITIONS ARISE WHERE
RESPIRATORS ARE NEEDED, USE ONLY NIOSH/MSHA RESPIRATORS APPROVED
FOR DUST, FUME AND MIST.
Ventilation:BATTERY CHARGING AREAS MUST BE ADEQUATELY VENTILATED TO
KEEP VAPOR AND MIST CONCENTRATIONS BELOW EXPOSURE LIMITS.
Protective Gloves:GLOVES APPROVED FOR SULFURIC ACID
Eye Protection:CHEMICAL GOGGLES, FULL FACE SHIELD.
Other Protective Equipment:ACID RESISTANT APRON.
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
CONTD FROM PRODUCT ID: PART NUMBER: G-6381E. THIS MSDS DESCRIBES
BATTERY ELECTROLYTE. FOR DRY BATTERY, SEE MSDS NUMBER CLGYW.
Chemical Properties
HCC:C1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=95.C, 203.F
B.P. Text:@ 760 MMHG
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:< 1MMHG@70F
Vapor Density:>1
Spec Gravity:1.22 TO 1.40
pH:NOT PROVIDED
Viscosity:NOT PROVIDED
Evaporation Rate & Reference:<1
Solubility in Water:100%
Appearance and Odor:CLEAR LIQUID NO ODOR
Corrosion Rate:NOT PROVIDED
Stability
Stability Indicator/Materials to Avoid:YES
CONTACT OF ELECTROLYTE WITH ORGANIC MATERIAL
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:SULFURIC ACID MIST, SULFUR DIOXIDE AND
CARBON MONOXIDE MAY BE RELEASED WHEN ELECTROLYTE DECOMPOSES.
Disposal
Waste Disposal Methods:ELECTROLYTE SHOULD BE HAULED TO A PERMITTED
TREATMENT FACILITY
Toxicology
Toxicological Information:NOT PROVIDED
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:NOT PROVIDED
Transport
Transport Information:DOT DESCRIPTION: CONSUMER COMMODITY ORM-D.
Regulatory
SARA Title III Information:THE CHEMICALS LISTED BELOW ARE TOXIC
CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF
TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT
(SARA) OF 1986 AND 40 CFR PART 372: SULFURIC ACID (CAS #
7664-93-9) < 50 %.
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:PROPOSITION 65: NOT APPLICABLE.